Проєкти / Gate Controller / TC-05

TC-05 · Stop gate while opening

Automation: reviewed NOT RUN

Edit

Що перевіряємо

Preconditions
State = OPENING; OPEN relay = ON
Steps
1. Start opening.
2. While State = OPENING press STOP (S).
3. Observe state and relays.
Expected state
STOPPED
Expected result
OPEN relay = OFF; CLOSE relay = OFF

Wokwi scenario

tests/TC-05.yaml

name: TC-05 Stop gate while opening
version: 1
author: Embedded QA
steps:
  - wait-serial: "Initial state: CLOSED"
  - write-serial: "O"
  - wait-serial: "OPENING"
  - delay: 200ms
  - write-serial: "S"
  - wait-serial: "STOPPED"